Dontopedia
Explore

Sgr 1806 20

From Dontopedia, the open, paraconsistent wiki. (Last updated 2026-06-06.)

Sgr 1806 20 has 60 facts recorded in Dontopedia across 8 references.

60 facts·56 predicates·8 sources

Mostly:rdf:type(4), rdfs:label(2), has ec observed(1)

Maturity scale raw canonical shape-checked rule-derived certified

Has Ec ObservedhasEcObserved

  • 12 MeV[6]all time · Part 526

Has Ec PredictedhasEcPredicted

  • 22.6 MeV[6]all time · Part 526

Has Ec RatiohasEcRatio

  • 0.53[6]all time · Part 526

Has Me V Hard Tail EnergyhasMeVHardTailEnergy

  • 12 MeV[6]all time · Part 526

Has Qpo Modes CounthasQpoModesCount

  • 9[6]all time · Part 526

Has Qpo Observed FrequencyhasQpoObservedFrequency

  • 57 Hz[6]all time · Part 526

Has Qpo Predicted FrequencyhasQpoPredictedFrequency

  • 54.8 Hz[6]all time · Part 526

Has Qpo RatiohasQpoRatio

  • 1.04[6]all time · Part 526

Has Ec ObservationhasEcObservation

  • 12[5]all time · Part 520

Has Ec PredictionhasEcPrediction

  • 27.9[5]all time · Part 520

Has Nearest Observed ModehasNearestObservedMode

  • 92.5[5]all time · Part 520

Has Qpo PredictionhasQpoPrediction

  • 67.4[5]all time · Part 520

Inbound mentions (13)

Other subjects in dontopedia point AT this entity as a value. These are inverse relationships — e.g. "X motherOf this subject" — and answer questions the forward facts can't. Grouped by predicate.

hasSubjectHas Subject(2)

assignedValueToAssigned Value to(1)

comparesPredictionToObservationCompares Prediction to Observation(1)

existForExist for(1)

hasEpeakForHas Epeak for(1)

hasQposForHas Qpos for(1)

hasTargetHas Target(1)

onlyForOnly for(1)

performedOnPerformed on(1)

providesMeasurementForProvides Measurement for(1)

showsEcForShows Ec for(1)

standsForStands for(1)

Other facts (48)

The long tail: predicates that appear too rarely to warrant their own section. Filter or scroll to find a specific one. Each row links to its source.

48 facts
PredicateValueRef
Has Genuine Mev Scale MeasurementMev Scale Measurement[3]
Has Mev Scale Measurement Value12[3]
Integral Ibis Epeak Value32.4[3]
E C Observed12[2]
E C Observed SourceCollazzi Et Al 2015[2]
E C Predicted22.6[2]
E C Ratio Evaluated Aswithin 50%[2]
Has Qpo Observed57[2]
Previous Ratio CauseOld Pdot[2]
Previous Ratio E C0.43[2]
Qpo Matches Predictiontrue[2]
Qpo Match Evaluated Asessentially exact[2]
Qpo Predicted54.8[2]
Qpo Ratio1.04[2]
Qpo SourceHuppenkothen Plus 14[2]
Ratio E C0.53[2]
Is Among26 Magnetarstrue[6]
Central to Discussionnull[3]
Best Match Exampletrue[2]
Improved Ratio FromUpdated Pdot[2]
Rdf:typeMagnetar[1]
Rdf:typeMagnetar[4]
Rdf:typeMagnetar[8]
Rdf:typeMagnetar[7]
Rdfs:labelSGR 1806-20[4]
Rdfs:labelSGR 1806-20[7]
Has Qpo Frequency Predicted54.8 Hz[7]
Has Qpo Frequency Observed57 Hz[7]
Has Observed Value12 MeV[7]
Has Predicted Value22.6 MeV[7]
Has Measured Hard Tail12 MeV[7]
Has Qpo Mode Count9[7]
Measurement SourceCollazzi+15[4]
Has Measurement ScaleMeV-scale[4]
Has Ec Measurement12 MeV[4]
Qpo Prediction Qualityessentially exact[1]
Has Qpo Prediction Ratio1.04[1]
Has Predicted Qpo Frequency54.8 Hz[1]
Qpo Reported inHuppenkothen 14[1]
Has Qpo Frequency57 Hz[1]
Previous Calculation Based onold Pdot[1]
Previous Prediction Ratio0.43[1]
Has Prediction Ratio0.53[1]
Has Observed Ec12.0 MeV[1]
Has Predicted Ec22.6 MeV[1]
Analysed byCollazzi Et Al 2015[1]
Has Ec Value12 MeV[1]
Has NameSGR 1806-20[1]

Timeline

Timeline axis is valid_time — when each source says the fact was true in the world, not when Dontopedia learned about it. Retracted rows are kept for provenance; coloured stripes indicate the context kind.

analysedByblah/watt-activation/518
ex:collazzi-et-al-2015
bestMatchExampleblah/watt-activation/part-521
true
centralToDiscussionblah/watt-activation/part-522
null
e_cObservedblah/watt-activation/part-521
12
e_cObservedSourceblah/watt-activation/part-521
ex:collazzi-et-al-2015
e_cPredictedblah/watt-activation/part-521
22.6
e_cRatioEvaluatedAsblah/watt-activation/part-521
within 50%
hasEcMeasurementblah/watt-activation/519
12 MeV
hasEcObservationblah/watt-activation/part-520
12
hasEcObservedblah/watt-activation/part-526
12 MeV
hasEcPredictedblah/watt-activation/part-526
22.6 MeV
hasEcPredictionblah/watt-activation/part-520
27.9
hasEcRatioblah/watt-activation/part-526
0.53
hasEcValueblah/watt-activation/518
12 MeV
hasGenuineMevScaleMeasurementblah/watt-activation/part-522
ex:mev-scale-measurement
hasMeasuredHardTailblah/watt-activation/523
12 MeV
hasMeasurementScaleblah/watt-activation/519
MeV-scale
hasMeVHardTailEnergyblah/watt-activation/part-526
12 MeV
hasMevScaleMeasurementValueblah/watt-activation/part-522
12
hasNameblah/watt-activation/518
SGR 1806-20
hasNearestObservedModeblah/watt-activation/part-520
92.5
hasObservedEcblah/watt-activation/518
12.0 MeV
hasObservedValueblah/watt-activation/523
12 MeV
hasPredictedEcblah/watt-activation/518
22.6 MeV
hasPredictedQpoFrequencyblah/watt-activation/518
54.8 Hz
hasPredictedValueblah/watt-activation/523
22.6 MeV
hasPredictionRatioblah/watt-activation/518
0.53
hasQpoFrequencyblah/watt-activation/518
57 Hz
hasQpoFrequencyObservedblah/watt-activation/523
57 Hz
hasQpoFrequencyPredictedblah/watt-activation/523
54.8 Hz
hasQpoModeCountblah/watt-activation/523
9
hasQpoModesCountblah/watt-activation/part-526
9
hasQpoObservedblah/watt-activation/part-521
57
hasQpoObservedFrequencyblah/watt-activation/part-526
57 Hz
hasQpoPredictedFrequencyblah/watt-activation/part-526
54.8 Hz
hasQpoPredictionblah/watt-activation/part-520
67.4
hasQpoPredictionRatioblah/watt-activation/518
1.04
hasQpoRatioblah/watt-activation/part-526
1.04
improvedRatioFromblah/watt-activation/part-521
ex:updated-pdot
integralIbisEpeakValueblah/watt-activation/part-522
32.4
isAmong26Magnetarsblah/watt-activation/part-526
true
measurementSourceblah/watt-activation/519
ex:collazzi+15
previousCalculationBasedOnblah/watt-activation/518
old Pdot
previousPredictionRatioblah/watt-activation/518
0.43
previousRatioCauseblah/watt-activation/part-521
ex:old-pdot
previousRatioE_cblah/watt-activation/part-521
0.43
qpoMatchesPredictionblah/watt-activation/part-521
true
qpoMatchEvaluatedAsblah/watt-activation/part-521
essentially exact
qpoPredictedblah/watt-activation/part-521
54.8
qpoPredictionQualityblah/watt-activation/518
essentially exact
qpoRatioblah/watt-activation/part-521
1.04
qpoReportedInblah/watt-activation/518
ex:huppenkothen-14
qpoSourceblah/watt-activation/part-521
ex:huppenkothen-plus-14
ratioE_cblah/watt-activation/part-521
0.53
labelblah/watt-activation/519
SGR 1806-20
labelblah/watt-activation/523
SGR 1806-20
typeblah/watt-activation/518
ex:Magnetar
typeblah/watt-activation/519
ex:Magnetar
typeblah/watt-activation/517
ex:Magnetar
typeblah/watt-activation/523
ex:Magnetar

References (8)

8 references
  1. [1]51814 facts
    customctx:discord/blah/watt-activation/518
  2. [2]Part 52115 facts
    customctx:discord/blah/watt-activation/part-521
  3. [3]Part 5224 facts
    customctx:discord/blah/watt-activation/part-522
  4. customctx:discord/blah/watt-activation/519
    • full textwatt-activation-519
      text/plain2 KBdoc:agent/watt-activation-519/6fff3ae6-c08b-4c29-81d1-1896383fb4af
      Show excerpt
      [2026-03-23 00:52] xenonfun: ⏺ The honest answer is that the observational data we have is already most of what's published. The bottleneck is: For E_c (burst cutoffs): - Only SGR 1806-20 has a genuine MeV-scale measurement (12 MeV fro
  5. [5]Part 5204 facts
    customctx:discord/blah/watt-activation/part-520
  6. [6]Part 5269 facts
    customctx:discord/blah/watt-activation/part-526
  7. customctx:discord/blah/watt-activation/523
    • full textwatt-activation-523
      text/plain3 KBdoc:agent/watt-activation-523/1e284aca-e1a0-46ac-81ee-3fbc28c76d84
      Show excerpt
      [2026-03-23 01:26] xenonfun: ⏺ Here's the honest status: What we have: - 26 magnetars with spin parameters from McGill/ATNF - 5 with QPO detections (SGR 1806-20: 9 modes, SGR 1900+14: 4, SGR 0526-66: 1, SGR 1935+2154: 1, SGR J1550-54
  8. customctx:discord/blah/watt-activation/517
    • full textwatt-activation-517
      text/plain2 KBdoc:agent/watt-activation-517/cf7c78b2-1cf7-4523-97b8-9d0870238180
      Show excerpt
      [2026-03-22 22:46] xenonfun: 6 JSONL files with 101 data points each ready in harmonic-core/snapshots/. The dashboard Field tab should now be switchable after the server restart. The panels will show data once we wire JSONL loading into

See also

Keep researching

Missing something or suspicious of what's here? Kick off a research session — a Claude agent will investigate, cite its sources, and file new facts into a dedicated context you can review before accepting into the shared view.